<link rel="stylesheet" href="styles.f3b1fba60ec7970c.css">
FUT Minna Institutional RepositoryFederal University of Technology, Minna

Interchangeable Range of Ozone Concentration Simulation for Low Cost Reconfigurable Brass Gas Cell

dc.contributor.authorEn Marcus, Tay Ching
dc.contributor.authorDavid, Michael
dc.contributor.authorYaacob, Maslina
dc.contributor.authorSalim, Mohd Rashidi
dc.contributor.authorIbrahim, Mohd Haniff
dc.contributor.authorNgajikin, Nor Hafizah
dc.contributor.authorAzmi, Asrul Izam
dc.contributor.authorIdrus, Sevia Mahdaliza
dc.contributor.authorBuntat, Zolkafle
dc.date.accessioned2021-06-17T13:01:26Z
dc.date.available2021-06-17T13:01:26Z
dc.date.issued2014
dc.description.abstractUltraviolet absorption spectroscopy is reliable for ozone concentration measurement. Concentration range and optical path length are inversely related based on theoretical calculation and observation of previous work. However, gas cells for ozone application are typically not expandable. In addition, they incur cost for custom fabrication. Here we design a reconfigurable brass gas cell that may interchange optical path length between 5.6 cm and 10.8 cm. Components are available at low cost, easy to joint and ready to use. Theoretical background and gas cell structure are discussed. Practical transmittance values between e -0.65 and e -0.05 are proposed for theoretical calculation of concentration via Beer-Lambert law. The concentration values are used in SpectralCalc.com gas cell simulation to obtain transmittance. Both approaches yield comparable result. Simulation result shows concentration range of 5.6 cm optical path length gas cell (31.82 ppm to 413.67 ppm) is wider than concentration range of 10.8 cm optical path length gas cell (16.50 ppm to 214.49 ppm). Simulation condition is at transmittance from 0.5291 to 0.9522, sampling wavelength 253.65 nm, temperature 300 K and pressure 1 atm. Thus, we strongly recommend short optical path length gas cell (5.6 cm) for wide range of concentration measurement (31.82 ppm to 413.67 ppm)en_US
dc.description.sponsorshipThe authors are grateful to Universiti Teknologi Malaysia (UTM) for supporting this research work under Research University Grant (RUG) Scheme, grant no: 05J60 and grant no: 04H35, and UTM Zamalah Fellowshipen_US
dc.identifier.issn2180–3722
dc.identifier.urihttp://repository.futminna.edu.ng:8080/jspui/handle/123456789/3508
dc.language.isoenen_US
dc.publisherPenerbit UTM Press, Universiti Teknologi Malaysia.en_US
dc.subjectConcentration; design; gas cell; low cost; optical path length; ozone; range; simulationen_US
dc.titleInterchangeable Range of Ozone Concentration Simulation for Low Cost Reconfigurable Brass Gas Cellen_US
dc.typeArticleen_US

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Interchangeable Range of Ozone Concentration Simulation for Low Cost.pdf
Size:
842.35 KB
Format:
Adobe Portable Document Format
Description:

License bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description: