Abstract
Lack of reliable access to modern energy in Minna Niger state results in
households ’use of inefficient alternatives especially fossil fuel generators for
domestic purposes. The study analyses indoor air pollution from households ’use
of generator with a view to determining their exposure to Carbon monoxide. The
concepts of energy access, poverty and generator pollution were reviewed. The
research employed empirical approaches and adopted the multi-stage sampling
technique. The study area has a population of 63,873 households. MSA Altair 5X
Multigas detector was employed in the detection of pollution (CO) levels
emanating from the generator use. It revealed that inefficient use of generator,
generates 60 ppm, above the WHO and NAAQS threshold of 10 ppm. 66.4% of the
generator using households are exposed to dangerous levels of CO pollution from
generator use at ≤4 meters ’distance in Minna, Nigeria. The study concluded that
households ’access to adequate electricity de-emphasizes the need for generator
ownership and use. Households ’ liveability is undermined by high level of pollution.
It recommended enlightenment on the dangers of exposure to carbon monoxide
and that generators should be operated at a minimum distance of 4 meters away
from residential buildings.