Development of Innovative Plate Load Testing Equipment for In-Situ Saturated Clays Soils
Loading...
Date
Journal Title
Journal ISSN
Volume Title
Publisher
geotechnics
DOI
Abstract
This study proposes a method of gradually loading plate load on-site using lever arms
to squeeze out pore water from clayey soils, allowing the soil to settle. Several types of tests were
conducted, including a conventional field plate load test (CFPLT), a numerical field plate load test
(NFPLT) and an innovative field plate load test (IFPLT) proposed in this study. Three trial pits with
soils of varied engineering properties were studied using CFPLT, which employed the use of a heavy
jack for load application, the NFPLT test using PLAXIS and an IFPLT, which employed a lever arm to
magnify the applied static load. Disturbed soil samples collected from these trial pits were tested
for index properties while the undisturbed soil samples were tested using the undrained triaxial
compression test (UTCT) and laboratory consolidation tests. The results of the index properties
classified these three clay soils as silt of low plasticity (ML) for clay from site 1, and clay of low
plasticity (CL) for clay from site 2 and 3. The cohesion and angle of internal friction from the UTCT
recorded cohesion values were 28, 29 and 37 kN/m2
for sites 1, 2 and 3, respectively, while the angle
of internal friction values were 13, 8 and 6◦
for sites 1, 2 and 3, respectively. The plate load testing
using the three methods showed similar graph pattern except that the allowable load occurred at
approximately 350 kN/m2
for the CFPLT and 150 kN/m2
for the IFPLT. The high value of bearing
capacity in CFPLT is due to the short period of time taken to load from a jack, which allowed the
test to be completed within a short period of time. The ultimate bearing capacities computed from
the laboratory test have values of 315.0, 231.0 and 270.0 kN/m2
for sites 1, 2 and 3, respectively.
These values agree closely with the bearing capacities obtained for CFPLT but higher than the values
recorded for the IFPLT. This is probably due to the long period of sustained loading during testing,
which allowed for dissipation of pore water during each loading. Settlements obtained using the
IFPLT were close to 25 mm, which is recommended as minimum settlements for building structures
BS 8004, 1986.
Description
Keywords
Citation
: Umaru, I.; Alhaji, M.M.; Alhassan, M.; Adejumo, T.E.; Alkali, B.; Birniwa, A.H.; Jagaba, A.H. Development of Innovative Plate Load Testing Equipment for In-Situ Saturated Clays Soils. Geotechnics 2023, 3, 142–160. https://doi.org/ 10.3390/geotechnics3020009