Determination of Yearly Performance and Degradation Rate of Electrical Parameters of a Monocrystalline Photovoltaic Modules in Minna, Central Nigeria
Loading...
Date
Journal Title
Journal ISSN
Volume Title
Publisher
Journal of Energy Research and Reviews, Vol. 9 (4), pp 71-78.
DOI
Abstract
Outdoor degradation analysis was carried out on a monocrystalline PV module rated 10 W using the
CR1000 software-based Data Acquisition System (DAS). The PV module under test and
meteorological Sensors were installed on a metal support structure on the same test plane. The
data obtained was monitored from 09:00 to 18:00 hours each day continuously for a period of four
years, from December 2014 to November 2018.The experiment was carried out near the Physics
Department, Federal University of Technology, Minna (latitude 09o37'N, longitude 06o32'E, and 249
meters above sea level). The sensors were connected directly to the CR1000 Campbell Scientific
data logger, while the module is connected to the logger via electronic loads. The logger was
programmed to scan the load current from 0 to 1 A at intervals of 50mA every 5 minutes, and
average values of short-circuit current, (Isc,) open-circuit voltage, (Voc), current at maximum power,
(Imax), the voltage at maximum power,(Vmax), power and maximum power obtained from the modules
together with the ambient parameters are recorded and logged. Data download at the data
acquisition site was performed every 7 days to ensure effective and close monitoring of the data
acquisition system (DAS). At the end of each month and where necessary, hourly, daily and monthly
averages of each of the parameters-solar irradiance, solar insolation, wind speed, ambient and
Original Research Article
Olakanmi et al.; JENRR, 9(4): 71-78, 2021; Article no.JENRR.80655
72
module temperatures, and the output response variables (open-circuit voltage, Voc, short-circuit
current, Isc, the voltage at maximum power, Vmax, current at maximum power, Imax, efficiency, Eff, and
fill factor, FF) of the photovoltaic modules were obtained.Yearly averages of the performance
variables were obtained to ascertain the performance, degradation rate, and lifespan of the module.
The module performance for the four years of study was compared with Standard Test Condition
(STC) specifications. The maximum power achieved at 1000W/m2 for the four years of study are
0.711W, 1.82W, 0.50W, and 0.22W representing 7.11%, 18.39%, 5.0% and 2.25% of the
manufacturer’s 10W specification. Module efficiency at 1000W/m2 for the four years of study is
3.30%, 10.12%, 3.98%, and 2.82% respectively as against the manufacturer's STC specification of
46%. Accordingly, Module Performance Ratios for the PV module investigated were 0.072, 0.22,
0.087, and 0.061respectively. For the Rate of Degradation (RoD), it was observed that Open-Circuit
voltage (Voc), Short-Circuit Current (Isc), Power-Output (P), and Maximum Power (Pmax), has an
average yearly degradation rate of 1.06V, 0.002A, 0.082W and 0.142W representing
4.9%,0.30%,0.56%, and 1.4%respectively for the four years of study.