SENSITIVITY ENHANCEMENT FOR A REFLECTIVE OZONE MONITOR
Loading...
Date
Journal Title
Journal ISSN
Volume Title
Publisher
SCHOOL OF POSTGRADUATE STUDIES UNIVERSITI TEKNOLOGI MALAYSIA
DOI
Abstract
In the design of ozone sensor, sensitivity is one of the performance criteria that is considered [1 -3]. Sensor sensitivity is the minimum input that will generate a readable output change[4]. For sensors based on absorption spectroscopy, sensitivity is directly proportional to optical path length [3, 5-8]. In the conventional design of a transmission type optical sensor, the beam of light is radiated parallel to the gas cell; hence a transmission type gas cell will have optical path length approximately equal to the length of the gas cell[3]. For our design, the basic laws of reflection are explored that is the angle of reflection equals the angle of incidence[9] in combination with factors that favours the reduction of head loss in fluid flow (the sudden enlargement transition is considered)[10]