Abstract
The continuous firing of a gas turbine
engine make it become fouled with airborne contaminants
like sand, dust, oil, salt and smoke which encrust the
compressor and turbine components. Generally, the
deterioration of axial flow compressors is a major cause of
loss in gas turbine output and efficiency. The cleaning of the
gas turbine compressor is the most effective method of
preventing fouling. Cleaning maximises fuel efficiency, the
life of the machine and recovers majority of lost power
output. The most effective technique of cleaning the
compressor and the air-filter of a gas turbine is the offline
method. The technique includes injecting water into the
compressor when the turbine is turned at cranking speed
and requires the turbine to be shut down. This paper
presents the performance evaluation of Geregu power plant
gas turbine after a bi-annual maintenance operation. The
performance parameters such as compressor pressure ratio,
compressor discharge temperatures, turbine exit
temperatures and power output improved significantly after
the bi-annual maintenance operation. The generation
utilization index increased from 0.55 to 0.90 andthe
capacity utilization Index increased from 0.51 to 0.85 after
the bi-annual maintenance operation. The station reliability
index was 0.47 two months before the bi-annual
maintenance operation but increased to 0.99 two months
after maintenance, resulting to a total power generation
increase from 66,000MWh two months prior to the biannual maintenance operation to 140,000MWh two months
after the maintenance.