Microorganisms associated with corrosion of water pipelines in Minna, Niger State
| dc.contributor.advisor | Mohammed, S. S. D. | |
| dc.contributor.advisor | Ibrahim, A. | |
| dc.contributor.author | Oyewole, Oluwafemi Adebayo | |
| dc.contributor.author | Oyeleke, S.B. | |
| dc.date.accessioned | 2021-06-04T14:13:31Z | |
| dc.date.available | 2021-06-04T14:13:31Z | |
| dc.date.issued | 2011 | |
| dc.description.abstract | Micro organisms associated with corrosion of water pipelines in Barkin-Sale, Bosso, Chanchaga, Keteren-Gwari, Maikunkele and Kwangila areas of Minna metropolis in Niger State of Nigeria were isolated. Corroded water pipes and soil samples were analysed for microbiological and physicochemical properties between the months of February and July, 2008. Bacteria isolated were Desulfovibrio desulfuricans, Desulfotomaculum nigrificans, Thiobacillus thiooxidans, Lactobacillus lactis, Clostridium perfringens, Pseudomonas aeruginosa, and Bacillus cereus var mycoides, B. subtilis, B. cereus and Staphylococcus aureus while fungi isolated were Aspergillus niger, A. fumigatus, Penicillium notatum, Candida tropicalis, Mucor mucedo, Torulopsis candida, Geotrichum candidum and Fusarium solani The bacterium most frequently isolated was D. desulfuricans (56.67%) while the fungus with the highest occurrence was A. niger (25.00%). The mean total aerobic bacterial counts ranged from 3.50x103cfu/g to 7.16x104cfu/g, mean total anaerobic bacterial counts ranged from 5.59x104cfu/g to 7.69x106cfu/g and the mean total fungal count ranged from 3.0x103 cfu/g to 5.63x105cfu/g. From the data, there were significant differences (p | en_US |
| dc.identifier.citation | Oyewole, O.A., Oyeleke, S.B., Mohammed, S. S. D. & Ibrahim, A. (2011). Microorganisms associated with corrosion of water pipelines in Minna, Niger State, Nigerian Journal of Technological Research, 6(2), 18-24. | en_US |
| dc.identifier.uri | http://repository.futminna.edu.ng:8080/jspui/handle/123456789/1227 | |
| dc.language.iso | en | en_US |
| dc.publisher | Nigerian Journal of Technological Research | en_US |
| dc.subject | Microbiology | en_US |
| dc.subject | Corrosion | en_US |
| dc.subject | water pipes | en_US |
| dc.subject | bacteria | en_US |
| dc.title | Microorganisms associated with corrosion of water pipelines in Minna, Niger State | en_US |
| dc.type | Article | en_US |
Files
Original bundle
1 - 1 of 1
Loading...
- Name:
- Microorganisms Associated with Corrosion of Water Pipelines in Minna, Niger State.pdf
- Size:
- 2.86 MB
- Format:
- Adobe Portable Document Format
- Description:
License bundle
1 - 1 of 1
Loading...
- Name:
- license.txt
- Size:
- 1.71 KB
- Format:
- Item-specific license agreed upon to submission
- Description: