Mathematical Modeling of a Flat Plate Solar Collector with Eutectic Salts as Phase Change Material
Loading...
Files
Date
Journal Title
Journal ISSN
Volume Title
Publisher
Arid Zone Journal of Engineering, Technology &Environment
DOI
Abstract
Solar energy is the most promising heat source for meeting energy demand
without having negative impact on the environment. Solar energy is, however,
intermittent in nature and time dependent energy source. In order to mitigate
the intermittent supply of solar energy for water heating, the use of phase
change material (PCM) comes into play. The PCM acts as a heat source for the
solar heating system when the intensity of the solar radiation is low or no longer
active. Knowledge about the thermal effectiveness of solar collector with PCM is
paramount. So, this study developed a mathematical model to evaluate the
thermal behavior of a flat plate solar collector integrated with a phase change
material (PCM). This mathematical model developed for the flat-plate with PCM
was based upon the conservation and heat transfer equations and used to
predict the thermal behavior of integrated phase change material in solar
collector during thermal storage. The energy balance equations for the flat-plate
heating components of the collector and PCM were formulated numerically. The
model was used to investigate the effect of inlet water temperature, water mass
flow rate, outlet water temperature and the melt fraction during charging and
discharging modes at each of the respective nodes. A comparison was made with
a collector with and without PCM. The results show that charging and
discharging processes of PCM have multiple stages. The addition of PCM in the
first stage causes a decrease in temperature during charging and an increase
during discharging. The highest water temperatures reached for the collector
without and with a phase change material were approximately 51 and 74°C
respectively Comparisons were also made between the simulated and
experimental data for the solar water heater without and with PCM. Minimum
inlet water temperatures of 41.54 and 36°C were observed for the simulated
and experimental model while, 42.69 and 74°C were both recorded for outlet
temperatures respectively, for solar water heater without PCM. For the solar
water heater with PCM, the inlet temperatures for the simulation and
experimental model were found to be 42°C and 56°C respectively. A maximum
outlet water temperature of 108°C was obtained from the experimental model
compared to 45°C obtained from simulation. The temperature of the hot
water obtained was remarkable and sufficiently enough for many domestic and
industrial applications. Finally, the solar water heating system with phase change
materials finds useful application and acts as a renewable energy resource in
regions where there is inconsistent or poor sunlight.