ASSESSMENT OF FIRE PREVENTION STRATEGIES IN THE DESIGN OF HIGH-RISE CONDOMINIUM BUILDINGS IN VICTORIA ISLAND, LAGOS STATE, NIGERIA
Loading...
Date
Authors
Journal Title
Journal ISSN
Volume Title
Publisher
DOI
Abstract
High-rise is generally a building that is greater than (22.5 m), and with 7 to 10 stories. They
could also mean structures with improved construction activities and enriched with
technology that will help in reducing land scarcity, urban density and can accommodate
large families in a lesser space. Condominium on the other hand, is a building divided into
several apartments or units, and each unit is occupied or managed by different individuals
or people. It could also be used for residential, commercial and or industrial purposes.
Despite the enormous advantages associated with high-rise buildings, there are challenges
facing its development especially in Nigeria. The most notable among its risks is fire
outbreak. The multiple floors in the building usually create a cumulative effect that requires
many occupants to travel through vertical distances on stairs which will create escape
problem during fire outbreak. Fire outbreak in high-rise buildings is always terrible as the
occupants population make escape difficult or tedious. This study however, assesses fire
prevention strategies available in of some high-rise condominium buildings in Lagos state,
in order to suggest most suitable ones that can help in saving lives and properties. To
achieve this, the researcher uses both qualitative and quantitative data collection through
the use of structured observation schedule and questionnaires issued to the occupants of the
selected high rise condominium buildings in Victoria Island, Lagos state. Descriptive
research was adopted on selected high-rise condominium buildings. However, eleven (11)
high-rise buildings were selected out of five hundred and eighty six (586) buildings using
simple random and purposive sampling technique. Out of three hundred (300) close-ended
questionnaires issued, two hundred and forty three (243) were returned. Data collected were
analysed through descriptive statistics (frequency and percentages), pie charts and bar
charts. Findings however, shows that 80% of the buildings observed makes used of active
fire prevention strategies though some are not functional. In addition, 77% of the buildings
have good ventilation. Many occupants of the selected high-rise buildings responded that
most fire outbreaks are caused by electrical faults. Also, 52% of them however, responded
not to have come across any fire safety instruction. As a result many occupants have little
or no knowledge on fire safety measures and facilities within their building. This is why the
researcher recommends that electrical cables and fittings should be of good quality and
should be properly installed and monitored. Passive fire prevention strategies recommended
are building form, shape of the roof, compartmentation of fire, intumescent coating, photo
luminescent marking and fire resistance materials. More so, the occupants of such building
should have requisite knowledge on fire safety instructions through awareness, education
and information on the operational methods of any available fire prevention measures in the
building as that will increase occupant’s cautiousness on fire risks. All these should be
applied in designs and constructions of high-rise condominium buildings.