Geoelectrical Investigation For Groundwater Potential and Aquifer Protective Capacity of Overburden Units at Unions Site, Gidan kwano Campus, Federal University of Technology, Minna, North Central, Nigeria
Loading...
Date
Journal Title
Journal ISSN
Volume Title
Publisher
LAPAI JOURNAL OF APPLIED AND NATURAL SCIENCES
DOI
Abstract
Evaluation of groundwater potential was carried out at Northern part of Gidan kwano campus, Federal
University of Technology, Minna. Schlumberger electrode configuration was adopted with maximum
current electrode spacing (AB/2) of 100 m. The profile separations of 100 m with inter vertical
electrical soundings (VES) point spacing of 100 m. Total of sixty (60) vertical electrical soundings
station were covered. The interpretation revealed three distinct geologic layers. These include topsoil
with resistivity values between 11.41 and 1009 ohm-m and thickness is relatively thin and ranges
between 1 and 6m, The weathered/fractured layer has resistivity values from 11 to 963ohm-m with
thickness from1 to 45m indicate high degree of weathered/fracture and/or water saturation, The fresh
basement has resistivity values that range between12 and 2983 ohm-m. All the soundings 3-layered
and characterised by A, H and Q curve types. The area was categorised into high, medium and low
groundwater potential zones. Twenty five (25) VES points were delineated as ground water zones
having weathered/fractured resistivity varies between 100 and 963 Ωm and thickness ranging from 5 –
45m. The characteristic longitudinal unit conductance from 0.01 to 1.84 mhos. About 30% of the VES
points fall within the good rating suggesting generally poor overburden protective capacity around the
study area.
Description
Citation
J. Shehu, U. D. Alhassan, K. A. Salako, A. A. Rafiu & A. A. Adetona