The main objective of this study is to model water loss in the distribution network of
Shiroro District Metered Area, Minna, Niger State capital which has been facing severe
water supply scarcity in recent time. This scarcity has been further complicated with high
water loses via leakages. Hence, there is need for new and modern approaches which will
involve increased automation for estimation of water leakages. The hydraulic machine,
EPANET was used for the hydraulic modelling of the water loss in the networks of Minna
Water Treatment Plant and Shiroro District Metered Area, (DMA). Active Leakage
Control mechanism was adopted by deploying the use of modern leak detecting
equipment. Leaks were collected and measured from 37 nodes of Shiroro distribution
network. 24 hours Extended Period Simulation, (EPS), was carried out from leak prone
nodes by varying emitter coefficient from 0.1, 0.15, 0.2 and 0.3 respectively. The leakage,
Q
leaks
generated from the model using discharge coefficient and the values of observed
leaks Q
measured
from site were compared statistically using Nash-Sutcliffe efficiency
model to check the performance of the model. Data set collated were further utilised in
neural networks for the estimation of leakages. The leak generated using modern leak
detecting equipment was 1.3m
3
for eight (8) hours which was large because it was
unnoticed. Pearson Product Correlation of pressure and leak was found to be very high
positive and statistically significant. The NSE values obtained at optimum leakage
coefficient of 0.2 for 8th hour, 9th hour, 10th hour and 11th hour are 0.73, 0.68, 0.58 and
0.52 respectively. These values are good indictors of good performance. Model validation
for 20 pm, 21 pm and 22 pm hours in M. I. Wushishi Distribution Network gave NASH
values of 0.767, 0.668 and 0.601 respectively. For validation procedure using ANN, for
estimation of leakage at M. I. Wushishi Network, R
2
was 0. 65 and relative errors for
training and testing were 0.367 and 0.215 respectively. R
2
of 0.65 is an indication of better
performance of the model.in terms of leakage estimation. The performance of the model
has suggested that using the emitter coefficient of 0.2 can model the water leakage in
Shiroro and M. I. Wushsishi Water Distribution systems because of high correlation
between the simulated and the observed discharges. Variation of leakage exponent on the
performance of emitter equation in estimating leakages in water distribution system is
recommended.