SEISMIC PERFORMANCE OF NEPALESE SCHOOLS: A FULL-SCALE TEST OF A TYPICAL UNREINFORCED MASONRY WALL

dc.contributor.authorAminulai, Hammed O.
dc.contributor.authorBaiguera, Marco
dc.contributor.authorSextos, Anastatsios
dc.contributor.authorKashani, Mohammed M.
dc.date.accessioned2023-05-17T09:01:41Z
dc.date.available2023-05-17T09:01:41Z
dc.date.issued2022-06
dc.description.abstractThis paper presents the preliminary results of an experimental investigation on the seismic performance of a large-scale typical Nepalese school URM wall. Hence, it proposes a retrofitting method for its strengthening. The test subjected a 5m x 3m masonry brick wall, set in 1:6 cement–sand mortar, to a two-way ramp cyclic loading to determine shear cracking failure. The results show that the wall exhibited a Grade 2 type of failure that indicates a slight structural damage with both diagonal and horizontal cracks, at 4mm displacement loading, in the mortar joints. The failure pattern is similar to those obtained in similar works in the literature.en_US
dc.identifier.urihttp://repository.futminna.edu.ng:8080/jspui/handle/123456789/18984
dc.language.isoenen_US
dc.publisher12th National Conference on Earthquake Engineering, Earthquake Engineering Research Institute,en_US
dc.titleSEISMIC PERFORMANCE OF NEPALESE SCHOOLS: A FULL-SCALE TEST OF A TYPICAL UNREINFORCED MASONRY WALLen_US
dc.typeOtheren_US

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
1663491627_10377_Kashani.pdf
Size:
1.87 MB
Format:
Adobe Portable Document Format
Description:

License bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description: