<link rel="stylesheet" href="styles.f3b1fba60ec7970c.css">
FUT Minna Institutional RepositoryFederal University of Technology, Minna

Evaluation of Groundwater Potential and Aquifer Protective Capacity of Overburden Units in Paiko, North-Central Nigeria Using Integrated Hydrogeophysical Survey

dc.contributor.authorEjepu, J.S.
dc.contributor.authorIdris-Nda, A.
dc.contributor.authorAmadi, A.N.
dc.contributor.authorAlhassan, D.U.
dc.contributor.authorAbdullahi, D.S.
dc.date.accessioned2021-08-09T21:54:34Z
dc.date.available2021-08-09T21:54:34Z
dc.date.issued2016-11-23
dc.description.abstractA study on the evaluation of groundwater potential of Paiko area, North-Central Nigeria was conducted with the aim of determining the most suitable areas for siting of boreholes. The area is underlain by rocks of the basement complex comprising of migmatites gneisses and granites. To this end, hydrogeologic mapping with integrated geophysical method employing very low frequency Electromagnetic (VLF-EM) and Radial Vertical Electrical Sounding (RVES) methods have been utilized. Nine VIF-EM traverses with a separation of 100 m coupled with a station interval of 10 m in the E-W direction were adopted for the VLF-EM survey. Twenty-Seven RVES stations were occupied along the established traverses. Interpreted VLF-EM results reveal fractures trending principally in the NW-SE direction. Fracture anisotropy trends delineated from RVES survey also trend predominantly NW-SE. These trends correspond to the principal joint direction orientation from the field. Delineated geoelectric units from interpreted RVES survey are made up of clay, weathered and fractured rocks on top of the fresh basement rock and are characterised by 3-6 layer curve types. Prominent VLF-EM anomalies which are attributable to relatively thick unconsolidated weathered mantle at the north-western portion of the area holds more promise in terms of groundwater prospect. However, these weathered overburden areas show weak to pour protective capacity rating. Hence, drilling depths should target a minimum of 80 m for optimum yields and high quality groundwater supplyen_US
dc.identifier.citationEjepu, J.S., Idris-Nda, A., Amadi, A.N., Alhassan, D.U. & Abdullahi, D.S. (2016). Evaluation of Groundwater Potential and Aquifer Protective Capacity of Overburden Units in Paiko, North-Central Nigeria Using Integrated Hydrogeophysical Survey. Geological Society of Africa & Nigerian Mining and Geosciences Society (26th Colloquium of African Geology), ppen_US
dc.identifier.urihttp://repository.futminna.edu.ng:8080/jspui/handle/123456789/13018
dc.language.isoenen_US
dc.publisherGeological Society of Africa & Nigerian Mining and Geosciences Society (26th Colloquium of African Geology)en_US
dc.subjectGroundwater, Radial Vertical Electrical Sounding (RVES), Very Low Frequency Electromagnetics (VLF-EM)., Aquifer Protective Capacityen_US
dc.titleEvaluation of Groundwater Potential and Aquifer Protective Capacity of Overburden Units in Paiko, North-Central Nigeria Using Integrated Hydrogeophysical Surveyen_US
dc.typeArticleen_US

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Ejepu et al CAG-Conf.pdf
Size:
1.45 MB
Format:
Adobe Portable Document Format
Description:

License bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description:

Collections