IMPACT OF SEPTIC TANKS ON GROUNDWATER IN TUNGA, MINNA, NIGER STATE, NIGERIA
Loading...
Date
Journal Title
Journal ISSN
Volume Title
Publisher
Harvard Publications and Research International
DOI
Abstract
Soak-away contains high level
of organic matter, however
high concentration of this
organic matter will definitely
have an impact on
underground water quality
and it can be hazardous to
human health. The paper
examines the impact of septic
tank on groundwater quality
in Tunga area of Minna,
Niger State. It identifies the
physio-chemical and
bacteriological quality of the
ground water sample obtained
from groundwater sources
within the study area. It
determines the distance septic
tank can be from wells and
examine the level of
contamination in ground
water that septic tank
contributes to the water table
within the study area. The
study adopts qualitative and
quantitative research
approach, with a cross-section
of respondent selected from fixed points the study area.
Water samples were collected
taken to laboratory for test.
Questionnaire were
distributed to respondent in
the sample’s areas, response
collected were subjected to
statistical analysis. The result
shows that Cobalt were within
the range of 0.01mg/L to
0.23mg/L as indicated in A1 to
A5 of the study. This study
revealed that majority of the
water samples have traces of
Cobalt which can cause
paralysis in human system.
The findings revealed A3
ranked the highest with Lead
value of 0.101mg/l, A5 ranked
second with Lead value of
0.032mg/L and the least was
A1 with Lead value of
0.002mg/L. This Lead
presence can lead to damage to
the brain and nervous system;
it also slow growth and
development of human system
when consumed in drinking
water. The finding also shows
that Total Coliform was
present in the water samples
and the details revealed that
A4 ranked the highest with
16cfu/ml, A5 ranked second
with 13cfu/ml and A1 ranked
the least with 1cfu/ml. This
revealed that all the
groundwater source require
treatment before it can be safe
for drinking. This was also the
result shown on E.Coli in the
study which revealed the
presence of E.Coli (9cfu/ml - 34
cfu/ml) in all the groundwater
samples collected in the study
area. The finding revealed that
all the physio-chemical and
bacteriological quality of the
water samples collected and
analyzed from all the locations
tested for, are contaminated,
having traces of total and
faecal coliform counts greater
than zero as against the WHO
(2003), and NSDWQ (2006)
standards for drinking water
quality. The study concludes
that there was relationship
between distance from
groundwater source to septic
tank and the quality of
groundwater in Tunga. It
thereby recommends that
partners dealing with
environmental management
issues such as; Niger State
Environmental Management
Agency should work together
each time projects that involve
groundwater development and
onsite wastewater treatment
are to be implemented
Description
Citation
Garba et al., 2026