An Empirical Investigation Of Relationship Between Water/Cement + RHA Ratio And The Compressive Strength Of RHA Concrete
Loading...
Date
Authors
Journal Title
Journal ISSN
Volume Title
Publisher
International Journal of Engineering Research & Technology (IJERT)
DOI
Abstract
The study has empirically examined the relationship
between water/cement + RHA ratio and compressive
strength of RHA Concrete. Using a 35% replacement
of OPC with RHA, RHA concrete cubes were cast
with varying water/cement + RHA ratios (0.60, 0.63,
0.68, 0.72, 0.81, 0.86, 0.90 and 0.99 respectively)
and theircorresponding compressive strengths
determined. Applying a statistical technique (Pearson
Product moment correlation), it was established that
a positive correlation (0.63) exist between the
variables. The study further indicated that 39.46% of
the total variations in compressive strength of RHA
concrete for seven (7) days are due to the
water/cement + RHA ratio. The rest variations
(60.54%) need to be investigated.
Description
Keywords
Citation
Apeh (2013)