Design-Point Performance Simulation and Adaptation of a Gas Turbine Engine
Loading...
Date
Journal Title
Journal ISSN
Volume Title
Publisher
International Journal of Emerging trends in Engineering and Development
DOI
Abstract
A design point simulation and adaptation of anindustrial GE LM2500+ gas turbine engine is
presented. The design point is chosen when the engine runs steadily at operating point and
close to the nominal design condition at 29MW power output. The targeted performance
parameters are the fuel flow rate (FF), the compressor exit total pressure (P3), the compressor
turbine total exit temperature (T8) and the total exit temperature from the compressor (T3).
The values obtained from simulation using PYTHIA for the targeted performance parameters
are 2.57%, -0.5%, -0.52% and 1.11% for gas path pressure deviations at thecompressor
turbine, pressure deviations at the compressor, temperature deviations at thecompressor
turbine, and temperature deviations at the compressor respectively. The average percentage
deviation of the design valuesis over 1%. To achieve a better result, adaptation was carried
out and the values obtained from simulation of the adapted values were -0.000035%, 0%, -
0.00009%, and 0%. These values match reasonably with the targeted overall percentage
deviation of 1%