DESIGN AND CONSRUCTION OF AN ELECTRICAL POWER FAULT CIRCUIT INTERRUPTER
Loading...
Files
Date
Authors
Journal Title
Journal ISSN
Volume Title
Publisher
DOI
Abstract
The system is designed for under voltage and over voltage fault protection. It
continuously measures line voltage actual condition in an electrical wiring outlet to a safety
limit and disconnects power supply to the load if actual voltage exceeds the limits before
they become damage or ignite fire. In certain circumstances, household wiring and
appliances have been the source of fires in the home due to over voltage supply, overload and
the oxidation of the wire or wear over time.
This involves step down transformer, LM324 voltage comparator that senses input
line voltage and generate an output which is connected to the base of 2N2222 PNP transistor.
The system also used 555 timers Ie for alann and electromagnetic relay was also used for
switching and driving of alann.
The device detects over and under voltages to the load in the outlet. With this
infonnation, voltage comparator is used to evaluate whether a voltage difference exist at the
load. When the predetermined voltage threshold is met, the logic switching circuit executes
an emergency shutoff so that current to the appliance at that particular outlet is tenninated
and sound an al~nn to notify the user