Application of Electrical Resistivity Tomography for the Delineation of Ground Water Potential at Southern Part of Maikunkele Town, Niger State, Nigeria.
Loading...
Files
Date
Journal Title
Journal ISSN
Volume Title
Publisher
Lapai Journal of Applied and Natural Science
DOI
Abstract
Vertical Electrical sounding (VES) and 2-D Electrical Resistivity Tomography (ERT) were used to
study the groundwater potential for effective development and management in Maikunkele, Niger
State, Nigeria. Thirty (30) VES points were examined using Schlumberger configuration with current
electrode spacing ranging from 2.0 to 200 m. The VES data obtained were interpreted using
WinResist computer software. Furthermore, 2-D ERT with a 10 m interval between two sounding
points was applied using a dipole-dipole configuration. The 2-D inversion modelling of the Dipoledipole
data was interpreted using RES2DINV(R) software. The VES results revealed a heterogeneous
subsurface geologic sequence probe to 20.20 m and beyond. The variation in lithology consisted of
Lateritic soil/sand/clay/sandy-clay/clayey-sand/topsoil with resistivity varying from 115 Ωm to 1237
Ωm and underlay by a layer of clay with resistivity varying from 41 to 461 Ωm. The third layer was a
continuation of clay of resistivity ranging from 15.62 to 100 Ωm while the fourth layer in some VES
points was a combination of gravely sand with resistivity varying from 2674 to 4271 Ωm with a high
resistivity at the basement bedrock of 7920-16541 down to infinity. The VES results indicate that
VES points A5, B4, C5 and D5 have a promising aquifer potential. The fractured layer has a thickness
of 20-46 m and a resistivity value ranging from 27.2 Ωm to 409.4 Ωm. The presence of groundwater
in some parts of Maikunkele was determined and that was correlated with existing borehole logs for
proper sitting and development.