Evaluation of flexural strength of concrete beams reinforced with timber encased in permanent ferrocement forms
Loading...
Date
Journal Title
Journal ISSN
Volume Title
Publisher
Sustainable Cement and Concrete Research Group, ICACCR-2023
DOI
Abstract
A structural element must exhibit strength and stability for its intended use. This paper presents an investigation of a concrete beam reinforced with timber and encased in permanent ferrocement form for use as lintels for low-income housing. The 25 mm thick cement-sand ferrocement is reinforced nominally using a two-layered chicken mesh. The timber is placed in the tensile zone and the concrete cast around it is assumed to act in compression. The specimens were tested under a single-point flexural loading. The concrete design strength was 20 N/mm2 at 28 days. The induced loadings computed on the beam included the triangular load from the blockwalls and the self-weight of the concrete beam at the ultimate limit states which yielded a maximum bending moment of 0.22 KNm. However, the maximum carrying capacity based on first crack load yielded a maximum bending moments of 9.10 and 10.20 KNm for 50 x 50 mm and 50 x 75 mm timber reinforced ferrocement beams respectively. The computed maximum bending stress at the bottom of the fibre assuming uncased isotropic timber beams are 9.67 and 4.29 N/mm2 for the 50 x 50 mm and 50 x 75 mm timber respectively which is less than 10 percent of the ultimate bending strengths of the timber specimen. The results of the ultimate carrying capacity achieved would enable a choice of the size of timber beams positioned in the tensile zone of the permanent ferrocement forms to be made.