Application of the Geoelectric Characterization of the Aquifer in Kwakuti, North Central Nigeria
Loading...
Date
Journal Title
Journal ISSN
Volume Title
Publisher
ASUU Journal of Sciences, A Journal of Research and Development
DOI
Abstract
Vertical Electrical Sounding (VES), using Schlumberger array was carried
out to investigate the subsurface layer parameters used to delineate
groundwater potential of a 500 x 500 m area of land defined by latitude
9.416622 N to 9.421171 N and longitude 6.618314 E to 6.622833 E located
at Government Secondary School, Kwakuti, Niger State. A total of 36 VES
points at 100 m interval were sounded with a 100 m maximum half inter
current electrode spacing (AB/2). Result revealed that the study area is
underlain by three (3) geoelectric layers which include: the top soil with
104.5 to 2260.5 Ωm, 0.6 to 3.8 m and 0.6 to 3.8 m as its range of resistivity,
depth and thicknesses respectively; the weathered/fractured layer having
resistivity of 44.9 to 606.0 Ωm, depth of 4.3 to 28.6 m and thickness of 4.2 to
26.2 m was considered aquifer layer. The fresh basement has 919.4 to
3816.9 Ωm as its range of resistivity value with undefined depth and
thickness. The observed curve types were 100% H. Five (5) VES stations
C3, C4, D2, D5, and E4 were delineated as aquifer potentials of the study
area, having weathered/fractured resistivity, depths and thickness range
from 135.2 to 227.7 Ωm, 20.6 to 28.6 m and 17.8 to 26.2 m respectively
Description
Keywords
Citation
Alhassan D. U, Aliu, O.D, Alkali, A, Rafiu, A.A, Adetona A.A, Mohammed A and Salako, K.A.