Evaluation of Double Skin Facade as Heat Modulators for Office Buildings in Kano State
Loading...
Files
Date
Authors
Journal Title
Journal ISSN
Volume Title
Publisher
African Scholar Publications & Research International
DOI
Abstract
Abstract
The hot dry climate of Nigeria is characterized by a period of high temperature
and low relative humidity in which daily mean maximum indoor temperature for
most buildings reaches about 37°C with low indoor air velocity. As such, some
buildings tend to fulfil thermal requirements through dependence on mechanical
means of cooling to solve overheating. This results in exorbitant cost which is
disadvantageous specifically in profit oriented buildings like office buildings
where user comfort dictates the level of performance. This study investigates the
effectiveness of double-skin facades (DSFs) as heat modulators in the context of
office buildings in Kano State. Through a comprehensive analysis of climatic
conditions, building energy performance, and occupant comfort, the study
assesses the practicality and benefits of integrating DSFs in the region. The
research design employs explanatory and experimental approach whereby,
simulation tools, and empirical data are used to evaluate the thermal performance,
energy efficiency, and environmental impact of DSFs, providing valuable insights
for architects, designers, and policymakers involved in sustainable building
practices within Kano State. Double skin facade can increase indoor thermal
comfort in a building, with wider air gaps improving the overall performance of
office buildings and workers productivity. Simulation results show the behaviours
of a single skin façade of a selected case study to obtain the hourly temperature of
hottest day of the year in Kano and the result were obtained given the discomfort
hours for ground floor as 822 hours, first floor 795hours and second floor 770
hours respectively. Similarly, it was observed that a base case setup of 15 storey
Journal of African Innovation & Advanced Studies (JAIAS)
African Scholar
Publications
& Research
International
www.africanscholarpub.com
VOL. 02 NO. 2,
DECEMBER, 2023
E-ISSN 3027-1533
P-ISSN 3026-8648
2
africanscholarpublications@gmail.com
2023
of varying cavity depths of 450mm, 600mm and 750mm were simulated. The
predicted results stated that the 750mm walling setup double skin façade perform
best in the hot dry climate of Kano given a great reduction in discomfort of
505hours. Conclusively, the ability of designers to harness and use the building
envelope is crucial for achieving thermal comfort in hot and dry climates.
Meanwhile, passive strategies such as natural ventilation, daylighting, and solar
heat gain can also be incorporated into the fabric of the building. Based on these
findings, the study recommends the adoption of double skin facade designs for
office buildings in Kano State, as they can provide efficient thermal comfort and
energy savings