<link rel="stylesheet" href="styles.f3b1fba60ec7970c.css">
FUT Minna Institutional RepositoryFederal University of Technology, Minna

A Study of the Effect of Degradation on Industrial Gas Turbine Performance

dc.contributor.authorNasir, Abdulkarim
dc.contributor.authorUsman, Salihu .A.
dc.contributor.authorMohammed, Abubakar
dc.contributor.authorMuhammed, Shuaibu .N.
dc.contributor.authorBori, Ige
dc.date.accessioned2022-01-11T21:11:44Z
dc.date.available2022-01-11T21:11:44Z
dc.date.issued2016
dc.description.abstractComponent degradation is a very common problem associated with operating industrial gas turbines. The major components so affected by this phenomenon are compressor, combustor and turbine blades. This paper studied the effect of degradation on gas turbine performance. The study involved the analyses of operating parameters effects for Siemens gas turbine engines model SGT5 – 2000E coded GT11 and GT21 in the power stations at Geregu power stations. The parameters considered were ambient temperature, exhaust temperature, combustion chamber pressure and turbine entry temperature, GT11 is degraded while GT21 is newly installed engine both in the same location at Geregu I and II power stations in Ajaokuta, Kogi State in the North central part of Nigeria.Simulations were carried out using Gas turb 11 simulation software, results of engine performance parameters were compared and it was revealed that due to component degradation, the turbine entry temperature (TET) increased to 1049.67oC, the fuel flow increased by 8.49% and power fell by 7.14%. Consequently, the cost of power loss is one hundred and eighty-seven million, one hundred and eleven thousand, seven hundred and fifty-three naira ninety-two kobo (₦187,111,753.92k) over a period of one year for the degraded gas turbine.en_US
dc.identifier.urihttp://repository.futminna.edu.ng:8080/jspui/handle/123456789/14210
dc.language.isoenen_US
dc.publisherJournal of Science, Technology, Mathematics and Educationen_US
dc.relation.ispartofseriesvol.12;No 1
dc.subjectGas Turbine Degradationen_US
dc.subjectTurbine Entry Temperatureen_US
dc.subjectCombustion Chamber Pressureen_US
dc.titleA Study of the Effect of Degradation on Industrial Gas Turbine Performanceen_US
dc.typeArticleen_US

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
A study of the effect of degradation on industrial gas turbine performance.pdf
Size:
574.92 KB
Format:
Adobe Portable Document Format
Description:

License bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description: