Design of Aerated Lagoon for Fish Pond Wastewater Treatment
| dc.contributor.author | ADEOYE, Peter Aderemi | |
| dc.contributor.author | JIYA, John Musa | |
| dc.contributor.author | Akinyemi, Banjo | |
| dc.date.accessioned | 2021-06-10T08:41:29Z | |
| dc.date.available | 2021-06-10T08:41:29Z | |
| dc.date.issued | 2009-01-01 | |
| dc.description.abstract | A 16m by 10m aerated lagoon of depth 2.5m was designed for fish pond wastewater treatment. This was done to encourage the recycling aquaculture system of wastewater management. A sedimentation tank of 5.5m surface diameter with a total volume of 367.92m3 and side slope of 2:1 was also designed to take care of settleable solids in the wastewater. These were done after biological analysis of wastewater from a commercial fish farm has been done. From the analysis, the average ratio of four-hour permanganate value and Biological Oxygen Demand (BOD) was 1:5 which rendered the wastewater treatable by biological method (aerated lagoon). A diffused unit aerator of 3 hp compressor over a 50mm diameter pipe was also recommended with a retention period few days. | en_US |
| dc.identifier.uri | http://repository.futminna.edu.ng:8080/jspui/handle/123456789/2508 | |
| dc.language.iso | en | en_US |
| dc.publisher | Assumption University Journal of Technology | en_US |
| dc.subject | fish | en_US |
| dc.subject | aquaculture | en_US |
| dc.subject | Recycling | en_US |
| dc.subject | sedimentation | en_US |
| dc.subject | settleable solids | en_US |
| dc.subject | water | en_US |
| dc.title | Design of Aerated Lagoon for Fish Pond Wastewater Treatment | en_US |
| dc.type | Article | en_US |