Design and Perfomance Evaluation of a Short Recycled Concentric Tube Heat Exchanger for Raw Milk Pastuerization
Loading...
Date
Journal Title
Journal ISSN
Volume Title
Publisher
Journal of Advanced Research in Fluid Mechanics and Thermal Sciences
DOI
Abstract
The recycled concentric tube heat exchanger was designed with the principle of
recycled heat transfer technique over a short concentric tube, which successfully
constrained the heat transfer area of the conventionally long arranged or floating
tubes to a reduced size in terms of cycles/minute. Validation was then carried out
by experiment to ascertain its viability and the new concept was named cycle
pasteurization following its success. The total head loss of both water and milk side
of the heat exchanger were so negligible at 0.00002. The rate of heat, area, length,
no of cycles, log mean temperature difference and effectiveness of the heat transfer
were analyzed with respect to the pasteurizer and has exhibited very good
characteristics which have kept the milk composition and it organoleptic properties
safe for consumption. The most critical of the thermodynamic properties were
coefficient of heat transfer of 1.411 and 4.2319 W/m2 k and fouling factor of 0.7087
and 0.2363m2 ℃/W at the beginning and end of tube heat transfer respectively,
which are within the limits of pasteurization theory to keep the milk nutritive values
safe for consumption. This valuable equipment with 2 litres capacity for home use
and the concept of cycle pasteurization has effectiveness of 0.59 representing 98.3%
efficiency of the system. Indeed, the pasteurizer will complement the existing
conventional batch and flash pasteurization methods where arrangement of plates
and floating long concentric pipes are used which is characterized with the challenge
of micro-scale pasteurization.
Description
Citation
1