Geoelectric Evaluation of Aquifer Protective Capacity and Soil Corrosivity at Student Hostel, Gidan Kwano Campus, Federal University of Technology, Minna North Central Nigeria
Loading...
Date
Authors
Journal Title
Journal ISSN
Volume Title
Publisher
6th International Black Sea Scientific Research and Innovation Congress
DOI
Abstract
This paper presents result of 36 vertical electrical soundings carried out in Students hostel
Gidan Kwano, Federal University of Technology, Minna, north–central Nigeria to evaluate
aquifer protective capacity and soil corrosivity of overburden units in the study area. This was
done using the Schlumberger electrode array to obtain the data and was modeled using
computer iteration (Winresist software). The field data gives a resolution with 3–4 geoelectric
layers and the observed frequencies in curve types include: 47.20% of H, 13.88% of HA and
QA, 8.33% of KH and HK, 2.78% of A, K and AA. Using the longitudinal unit conductance
(S), the protective capacities of the study area were classified as 38.89% weak, 25% poor,
33.33% moderate, and 2.79% as good. The corrosivity ratings of the study area show that 0%
is strongly corrosive, 2.78% moderately corrosive, 2.78% slightly corrosive, and 94.44%
noncorrosive The results reasonably provide information on areas where industries can be sited
and iron pipes can be laid in order to safeguard the hydrological setting for resident’s safety in
the study area. Regions with moderate/good protective capacity are good sites for locating
boreholes.
Description
Citation
Jamilu A.S., Alhassan U.D., Alkali . A 2025