dc.date.issued2014-07
dc.descriptionhen synchronous generator is connected to a load, current flows through the armature. This current causes an armature or stator flux to be created which tends to counteract the air gap flux that is produced by field excitation. Air gap flux is reduced which causes the corresponding reduction in the terminal voltage. If the rotor excitation current is increased, the terminal voltage can be restored.en_US
dc.description.abstractIn this paper, various performance equations are derived from phasor diagrams of a three phase non-salient pole (cylindrical rotor) synchronous generator of known armature resistance and of ignored armature resistance for lagging, unity and leading power factor load. These equations are used to calculate the output parameters of non-synchronous generator and to plot the graphs of terminal voltage-armature current, torque angle-armature current, torque angle-terminal voltage, power-torque angle and torque-speed characteristics through simulation by MATLAB program for the purpose of illustrationen_US
dc.description.sponsorshipSelf sponsoreden_US
dc.identifier.citationEnesi, Yahaya Asizehi, Murtala ZUNGERU Adamu, and Ademoh Agbogunde Isah. "Analysis of non-salient pole synchronous generator using phasor diagrams." (2014).en_US
dc.identifier.issn1583-0233
dc.identifier.urihttp://irepo.futminna.edu.ng:8080/jspui/handle/123456789/30619
dc.language.isoenen_US
dc.publisherLeonardo Journal of Sciencesen_US
dc.subjectArmature resistance; Lagging power factor; Leading power factor; Nonsalient pole synchronous generator; Phasor diagrams; Unity power factoren_US
dc.titleAnalysis of non-salient pole synchronous generator using phasor diagramsen_US
dc.typeArticleen_US

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
8-Analysis of non-salient pole generator using phasor diagram.pdf
Size:
174.51 KB
Format:
Adobe Portable Document Format
Description:

License bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description: