Power Quality Disturbances Analysis using Two Forms of Wigner-Ville Distribution

dc.contributor.authorAhmad, Ashraf Adam
dc.contributor.authorAiroboman, Abel Ehimen
dc.contributor.authorAbdulaziz, Abdulrazaq
dc.contributor.authorHussaini, Habibu
dc.date.accessioned2023-01-25T18:46:42Z
dc.date.available2023-01-25T18:46:42Z
dc.date.issued2019-08
dc.description.abstractPower quality (PQ) is a major concern to both power utilities and consumers due to the widespread use of sensitive loads, power electronic devices and industrial equipments. This paper presents an analysis of PQ disturbances as a first step of their appropriate identification using time-frequency analysis. The research focused on the two most common forms of PQ disturbances in Nigeria: voltage sag and swell. The disturbance analysis was based on two basic forms of Wigner-Ville distribution (WVD); the windowed WVD and the filtered WVD used in conjunction with Hilbert transform. Results obtained showed that both forms of WVD are able to accurately capture the disturbances with concentration of energy along the main power supply frequency of 50Hz within the PQ disturbance duration of 0.1s. The proposed methodology showed that the WVDs would be a good signal processing method for subsequent classification of PQ disturbances in electrical power smart grid.en_US
dc.identifier.citationA. A. Ahmad, A. Ehimen Airoboman, A. Abdulaziz and H. Hussaini, "Power Quality Disturbances Analysis using Two Forms of Wigner-Ville Distribution," 2019 IEEE PES/IAS PowerAfrica, Abuja, Nigeria, 2019, pp. 424-428, doi: 10.1109/PowerAfrica.2019.8928911.en_US
dc.identifier.issnElectronic ISBN:978-1-7281-1010-3
dc.identifier.issnPrint on Demand(PoD) ISBN:978-1-7281-1011-0
dc.identifier.urihttp://repository.futminna.edu.ng:8080/jspui/handle/123456789/17830
dc.language.isoenen_US
dc.publisherIEEEen_US
dc.subjectPower Quality (PQ)en_US
dc.subjectWigner-Ville distribution (WVD)en_US
dc.subjecttime-frequency analysisen_US
dc.subjectvoltage sagen_US
dc.subjectvoltage swellen_US
dc.titlePower Quality Disturbances Analysis using Two Forms of Wigner-Ville Distributionen_US
dc.typeArticleen_US

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
CP3.pdf
Size:
945.09 KB
Format:
Adobe Portable Document Format
Description:
Power Quality Disturbances Analysis using Two Forms of Wigner-Ville Distribution