The study presents the results of an experimental program to investigate the strength
performance of Laterized concrete at elevated temperature. Four concrete mixes
incorporating 0, 10, 20 and 30% laterite as a replacement by weight of sand was
prepared. A concrete mix ratio of 1:2:4(Cement: laterite/sand: granite) with
water/cement ratio of 0.65 was used for the study. The laterite content in the fine
aggregate was varied from 0 – 30% at 10% interval. Specimens cured for 7, 14, 21
and 28days were subjected to uniaxial compressive loading tests at room and elevated
temperatures of 200, 400 and 600oC. Results showed that for the varying percentage
replacement of sand with laterite, compressive strength of laterized concrete
decreases; and with increase in temperature, the strength decreases. It was also
observed that an air-cooled lateritic concrete specimen has higher residual strength
values than water- cooled specimens. A maximum compressive strength value of
24.10N/mm2 was obtained for the mix with 30% laterite – 70% sand at 400oC which
indicates the strength of laterized concrete that is sufficient for use at elevated
temperature not exceeding 400oC.