Effect of vertical circular openings on flexural strength of reinforced concrete beam
Loading...
Date
Journal Title
Journal ISSN
Volume Title
Publisher
Magazine of Civil Engineering. Scientific and Technical Journal.
DOI
Abstract
Modern building construction techniques sometimes involve the passing of pipes or ducts for
water supply, electrification, and telecommunication through reinforced concrete beams to protect them
against mechanical damages and add aesthetic value to buildings. This study looks into the effect of vertical
circular openings on the flexural strength of the reinforced concrete beam. Two (2) sets of beam samples
were investigated during this study: computer simulated reinforced concrete (RC) beam using ANSYS 19.1
and laboratory cast. The results of the flexural strength test conducted show the following: Reinforced
concrete beam with vertical circular openings of diameter greater than 33.3 % of beam width (B) reduced
its flexural strength by at least 20 %; maximum compressive stress of concrete occurs at the openings
region of the beam; the difference in ultimate load capacity of finite element (FE) beam models and
experimental beam specimen is 3.5 %. It can be deduced that ANSYS software is an appropriate finite
element (FE) tool to predict the behaviour of RC beams. Hence, it is hereby recommended that the diameter
of the vertical circular opening in RC beam should not exceed 33.3 % of the beam width and its location
from beam support should not exceed L/6.
Description
Citation
Auta, S.M., Jamiu, O., Alhaji, A. (2021) Effect of vertical circular openings on flexural strength of reinforced concrete beam. Magazine of Civil Engineering. 106(6). Article No. 10601. DOI: 10.34910/MCE.106.1