Please use this identifier to cite or link to this item: http://repository.futminna.edu.ng:8080/jspui/handle/123456789/8684
Title: Simple and Fast Porosity Analysis of Concrete using X-ray Computed Tomography
Authors: Du Plessis, Anton
Olawuyi, Babatunde James
Boshoff, William Peter
Le Roux, Stephan Gerald
Keywords: X-ray computed tomography Pore size distribution Image analysis
Issue Date: 2016
Publisher: Materials and Structures
Citation: Du Plessis, A., Olawuyi, B.J., Boshoff, W.P. and Le Roux, S.G.
Series/Report no.: 49;
Abstract: X-ray computed tomography is a well-known technique to measure porosity in materials such as concrete, though this usually involves time consuming scans and complex analysis procedures. Many of these involve custom software or programming procedures. In this paper, a simplified procedure is presented and demonstrated using results obtained from basic procedures with commercial software packages, with minimal image processing. The same sample was subjected to scans ranging from 100 to 5 lm resolutions, demonstrating the multiscale ability of commercial CT scanners. Scans done at typical high-quality conditions (1 h duration) in comparison to very fast scans (5 min) are also presented and it is demonstrated that useful information is still obtained from such lower quality faster scans. This demonstrates the concept that X-ray CT is simple and cost-effective for research and industrial applications, not requiring expert 3D image analysis experience, for obtaining useful porosity information within the range of pore sizes resolvable by the technique.
URI: http://repository.futminna.edu.ng:8080/jspui/handle/123456789/8684
Appears in Collections:Building

Files in This Item:
File Description SizeFormat 
Mat & Str article_Anton, Olawuyi, Boshoff & leRoux.pdf2.25 MBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.