dc.description.abstractAs a need to reduce cost and minimize losses associated with downtime, early fault diagnosis has become necessary for more reliable, efficient, and productive industrial maintenance practices. This research was able to optimize the Enhanced Park Vector Approach (EPVA) by maximizing the advantage of the visualized Park vector plot, whose distortion is directly proportional to the degree of faults, to diagnose and compute the Fault Severity Index (FSI) of an occurred fault. The research was simulated on MATLAB using the mathematical model of an induction motor (IM). Iterative values of 0%, 1%, 3%, 5%, and 10% of inter-turn short circuit (ITSC) fault were used to study the state of the IM. The research was able to contribute to an effective mathematical computational method of computing the severity of fault using standard deviation and variance.en_US
dc.language.isoenen_US
dc.subjectEPVA, Park Vector Modulus, Fault Severity Index, Park Vector Plot, Standard Deviation, Varianceen_US
dc.titleFault Diagnosis in a Three-phase Induction Motor Using Enhanced Park Vector Approachen_US