Please use this identifier to cite or link to this item: http://repository.futminna.edu.ng:8080/jspui/handle/123456789/19616
Title: Assessment of Water Transport and Chemical Attack of Meta-Illite Calcined Clay Blended Cement in High-Performance Concrete
Authors: Nduka, David. O.
Olawuyi, Babatunde. J.
Cantero, Bias
González-Fonteboa, Belén
Keywords: durability properties; high-performance concrete; meta-illite calcined clay; superabsorbent polymers
Issue Date: 13-Nov-2023
Publisher: MDPI_Materials
Citation: Nduka, D.O.; Olawuyi, B.J.; Cantero, B.; González-Fonteboa, B. Assessment of Water Transport and Chemical Attack of Meta-Illite Calcined Clay Blended Cement in High-Performance Concrete.
Series/Report no.: Special Issue on Concrete Chemistry and Sustainability;https://doi.org/10.3390/ma16227149
Abstract: Rapid urbanisation causes a rise in the need for infrastructure, which in turn fuels the creation of additional concrete and further increases cement supplies. Activation of illite-based clay mineral and usage in concrete production is one of the sustainable ways to address the cement industry anthropogenic issues. This study evaluates the durability properties of water transport (water absorption, and capillary water absorption), and resistance to aggressive environments (5% solutions of hydrochloric acid, HCl; sodium sulphate, Na2SO4; and calcium chloride, CaCl2) of meta-illite calcined clay (MCC)-based high-performance concrete (HPC). For this purpose, concrete was produced with 5, 10, 15, 20, 25 and 30% MCC content in partial substitution of CEM II. Results from the water absorption tests indicate an average percentage value of 3.57%, 3.35% and 2.52% for all the observed mixes at 28, 56 and 90 days, respectively, with MCCC-10 HPC having an average best value of 2.23% across the curing ages. On all observed days, the 5 to 15% cement replacements had very close average water sorptivity value of 0.125 ± 0.001 mm/min0.5 with the control mix (0.113 ± 0.011 mm/min0.5). The aggressive environments exposure findings of the hardened MCC-based HPC specimens of 10 to 20% recorded an approximately 15% compressive strength loss in HCl, Na2SO4 and CaCl2 solutions over the 90 days of curing. In all, the HPC mixes of 5 to 15% MCC content obtained an average durability performance factor of 89%. As a result, these findings imply that MCC can replace cement in up to 15% of HPC production.
Description: This article is published in Materials, 2023, 16, 7149 (A Special Issue on Concrete Chemistry and Sustainability
URI: http://repository.futminna.edu.ng:8080/jspui/handle/123456789/19616
Appears in Collections:Building

Files in This Item:
File Description SizeFormat 
materials-16-07149-with-cover.pdfAn article published in Materials 16 - A Special Issue on Concrete Chemistry and Sustainability (MDPI publication)885.44 kBAdobe PDFView/Open