Please use this identifier to cite or link to this item: http://repository.futminna.edu.ng:8080/jspui/handle/123456789/18826
Title: The concurrent upshot of optical path-length and pressure on O3 absorption cross-section in relation to green communication
Authors: David, Michael
Enenche, Patrick
Alenoghena, Caroline
Keywords: Absorption cross-section
Green communication
Optical path length
Ozone gas
Pressure
Visible spectrum
Issue Date: 20-May-2022
Publisher: International Journal of Advances in Applied Sciences Vol. 11, No. 2, June 2022, pp. 97~106
Abstract: Ozone gas is a greenhouse gas. Accurate measurement of its concentration is dependent on the right value of the ozone gas absorption cross-section. In the literature, discrepancies and inconsistencies have been however linked with ozone gas absorption cross-section. In the literature, information on the pressure effect on pressures less than 100 mbar and greater than 100 but less than 1000 mbar is not available for the visible spectrum. Thus, creating an information gap that this manuscript is intended to fill up. This is the problem that has been addressed in this present work. The method of simulation with SpectralCalc is the method adopted for the present work. HITRAN 2012 simulator, available on spectralcalc.com, was used in simulating the ozone gas absorption cross-section to determine the simultaneous effect of optical path length and pressure at two peak wavelengths in the visible spectrum. Simulation outcomes were obtained for an optical path length of 10 cm to 120 cm showing that the optimum absorption cross-section value of 5.1084×10-25 m2 /molecule at 603 nm and 4.7182×10-25 m2 /molecule at 575 nm for gas cells length between 10 cm and 120 cm are obtained at peak points. Pressure values at which ozone gas absorption cross-section becomes a constant value of 5.1058×10-25 m2 /molecule at 603 nm and 4.7158×10-25 m2 /molecule at 575 nm is optical path length dependent. The percentage difference between 5.1084×10-25 m2 /molecule and 5.1058×10-25 m2 /molecule is 0.05% for all lengths of gas cells considered. Similarly, the percentage difference between 4.7182×10-25 m2/molecule and 4.7158×10-25 m2 /molecule is also 0.05% for all lengths of gas cells considered. These results are relevant for high-accuracy and high precision ozone gas measurements. Furthermore, efficient m
URI: http://repository.futminna.edu.ng:8080/jspui/handle/123456789/18826
ISSN: 2252-8814
Appears in Collections:Telecommunication Engineering

Files in This Item:
File Description SizeFormat 
The Cucurrent Upshoot of.pdf851.63 kBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.