Please use this identifier to cite or link to this item: http://repository.futminna.edu.ng:8080/jspui/handle/123456789/17106
Title: Effect of Ag2O/V2O5 substitution on the radiation shielding ability of tellurite glass system via XCOM approach and FLUKA simulations.
Authors: Olarinoye, Oyeleke
Alomairy, Sultan
Sriwunkum, C
Al-Buriahi, MS
Keywords: FLUKA
TeO2 glass, attenuation, shielding, gamma, neutron,
Issue Date: 2021
Publisher: IOP
Citation: 41. Olarinoye, I. O., Alomairy, S., Sriwunkum, C., & Al-Buriahi, M. S. (2021). Effect of Ag2O/V2O5 substitution on the radiation shielding ability of tellurite glass system via XCOM approach and FLUKA simulations. Physica Scripta, 96(6), 065308. https://doi.org/10.1088/1402-4896/abf26a
Abstract: This study focuses on the effect of Ag2O/V2O5 substitution on the radiation shielding ability of tellurite glass system with the chemical composition of xAg2O + 40TeO2 + (60− x)V2O5 with 0 < x < 50 mol%. FLUKA code was successfully employed for simulation the radiation interaction parameters of the glass systems. The results of the simulations were comparable with the predications of theory. Thereafter, several empirical equations were used to study the shielding ability of the glass systems against neutrons and charged particles. The results indicate that linear attenuation coefficient changes with energy and reaches maximum at 0.6 MeV(minimum at 10 MeV) with the values of 0.2806(0.109), 0.3181(0.121), 0.3771(0.1498), 0.409(0.168), 0.4588(0.1911), and 0.5162(0.2180) for x = 0, 10, 20, 30, 40, and 50 mol%, respectively. Beyond 5 MeV, the gamma ray constant was found in the order of (G)x=50 > (G)x=40 > G ( )x=30 > (G)x 20 = > (G)x 10 = > (G)x 0 = . For all the charged particles, the projectile range was noted in the order of(R)x=0 > (R)x=10 > (R)x=20 > (R)x=30 > (R)x=40 > (R)x=50. Finally, we provide an extensive comparative study between AVT-glass systems and standard traditional materials. The obtained results suggest the sample of x= 50 mol% as the best photon, fast neutron and charged particle shield amongst the present glass systems. Hence, AVT6 could be used in radiation safety applications as a shield.
URI: http://repository.futminna.edu.ng:8080/jspui/handle/123456789/17106
ISSN: https://doi.org/10.1088/1402-4896/abf26a
Appears in Collections:Physics

Files in This Item:
File Description SizeFormat 
40.pdf138.75 kBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.