Title: Development of a Test Rig for the Determination of Head loss and Friction Factor of a Polyvinyl Chloride (PVC) Pipes
Authors: Musa, N. A
Jiya, J. Y.
Aderoju, T. K
Keywords: Headloss
Friction Factor
PVC Pipes
Test rig
Water
Issue Date: 2016
Abstract: This paper reports the design, construction and performance evaluation of a test rig for determining the head loss and friction factor of PVC pipes of different diameters (13mm, 19mm and 25mm) transporting water. On performance evaluation, friction factors of 0.0121, 0.0396 , 0.0171 and head losses of 37.8mm, 25.2mm and 12.6mm for 13mm, 19mm, and 25mm diameter PVC pipes respectively were obtained.
URI: http://repository.futminna.edu.ng:8080/jspui/handle/123456789/16968
ISSN: 2225-0573
Appears in Collections:Mechanical Engineering

Files in This Item:
File Description SizeFormat 
Development of a Test Rig for the Determination of Headloss and.pdf1.03 MBAdobe PDFView/Open