Please use this identifier to cite or link to this item: http://repository.futminna.edu.ng:8080/jspui/handle/123456789/16476
Full metadata record
DC FieldValueLanguage
dc.contributor.authorOgunbode, Ezekiel Babatunde-
dc.contributor.authorMakun, C. S.-
dc.contributor.authorAngo, J. A.-
dc.contributor.authorHassan, I. O.-
dc.contributor.authorLawal, A. T.-
dc.contributor.authorIbrahim, S. M.-
dc.date.accessioned2023-01-02T16:15:34Z-
dc.date.available2023-01-02T16:15:34Z-
dc.date.issued2021-
dc.identifier.urihttp://repository.futminna.edu.ng:8080/jspui/handle/123456789/16476-
dc.description.abstractFibre reinforced concrete (FRC) is a conventional concrete mix that contains hydraulic cement, fine and coarse aggregate and discontinuous randomly distributed discrete fibre in concrete mix. Research has revealed that inclusion of fibre in concrete can enhance its performance characteristics in terms of durability, ductility, strength as well as energy absorption properties. Steel fibre concretes without Rice Husk Ash (RHA) have been successfully used for crack control in many structural applications. With the increasing amount of waste generation from various processes, there has been a growing interest in the utilization of waste in production of building materials to achieve potential benefits. This leads to sustainable, green and eco-friendly construction by reducing the price of components compare to disposing of the materials. This study examines the chloride resistance performance of green concrete composites containing steel fibre and 15% RHA. Four volume fractions of fibre from 0 to 2% at an interval of 0.5% and fibre length of 20 mm were used for CEM 1 (42.5 N) mixtures. The concrete was designed using the Department of Environment (DOE) mix design method to achieve a 28 days target strength of 30 N/mm2. Chloride resistance was assessed at 7, 28 and 56 days. The result shows that incorporation of steel fibre in RHA based concrete reduce the workability of concrete owning to its nature and affinity for water due to the presence of silica it contains. It was observed that incorporation of 1.0% steel fibre and 15% RHA in concrete provide a synergetic improvement on chloride resistance (durability) and strength when compared with control mix. The study recommends the utilization of steel fibre along with RHA in the production of a new alternative concrete composite that can resist chloride ingress in concrete composite.en_US
dc.language.isoenen_US
dc.publisherEnvironmental Technology & Science Journal (ETSJ)en_US
dc.relation.ispartofseries12(1);-
dc.subjectCementen_US
dc.subjectChloride resistanceen_US
dc.subjectFibre reinforced concreteen_US
dc.subjectRice husk ashen_US
dc.subjectSteel fibresen_US
dc.titleChloride Ingress Resistance of Rice Husk Ash Based Green Concrete Composites Containing Steel Fibresen_US
dc.typeArticleen_US
Appears in Collections:Building



Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.