Title: Analysis of non-salient pole synchronous generator using phasor diagrams
Authors: 1. Enesi, Yahaya Asizehi
Adamu, Murtala ZUNGERU
Isah, Ademoh Agbogunde
Keywords: Armature resistance; Lagging power factor; Leading power factor; Nonsalient pole synchronous generator; Phasor diagrams; Unity power factor
Issue Date: Dec-2014
Publisher: Leonar Journal of Sciences ISSN 1583-0233 Issue 25, July-December, 2014, p. 1-18
Series/Report no.: ;Issue 25
Abstract: In this paper, various performance equations are derived from phasor diagrams of a three phase non-salient pole (cylindrical rotor) synchronous generator of known armature resistance and of ignored armature resistance for lagging, unity and leading power factor load. These equations are used to calculate the output parameters of non-synchronous generator and to plot the graphs of terminal voltage-armature current, torque angle-armature current, torque angle-terminal voltage, power-torque angle and torque-speed characteristics through simulation by MATLAB program for the purpose of illustration.