dc.identifier.citationTWAKI, A. S., ALHASSAN, U. D., SALAKO, K. A., & SHEHU, J (2021) INVESTIGATION OF GROUNDWATER POTENTIAL USING ELECTRICAL RESISTIVITY METHOD AT GARATU SECONDARY SCHOOL, NIGER STATE, NIGERIAen_US
dc.identifier.urihttp://repository.futminna.edu.ng:8080/jspui/handle/123456789/14030-
dc.description.abstractEvaluation of groundwater potential was carried out at Garatu Secondary School, Garatu, Niger State Nigeria. Schlumberger electrode configuration was adopted with maximum current electrode spacing (A13/2) of 100 m. The profile separations was 100 m with inter vertical electrical soundings (VES) point spacing of 100 m from profile A to F. Total of thirty-six vertical electrical soundings station were covered. The interpretation revealed three distinctive geologic layers. The first layer which is the top layer has resistivity value ranging from 9071 - 16052 Dm, its depth and thickness varies between 1.3 -1.8 m and 1.3 -1.8 m respectively which corresponds to the geo-electrical parameters of fadama loam, weathered laterite and fractured basement The second layer has resistivity value of 205.4 - 322.212m, depth of 120 - 17.8 m and thickness of 10.5 - 16.0 m; this layer refers to the weathered/fractured basement. The resistivity of the third layer ranged from 858.4- 47772 Dm, its depth and thickness are undefined. The results dearly showed that the electrical resistivity method is suitable for and very efficient in investigating groundwater potential. The parameters (resistivity, depth and thickness) of the layers were employed to delineate the aquifer potential of the study area, their weathered/fractured layer with resistivity value varying from 148.9 to 218.9 Din while the depth and thickness ranged from 228 to 30.4 m and 21.0 to 273 m respectively. Five VES points C3, C4, 02, E4, and F2 were delineated as groundwater potential points of the areaen_US
dc.description.sponsorshipSelfen_US
dc.language.isoenen_US
dc.publisherJournal of Science, Technology, Mathematics and Education (JOSTMED), 17(1)en_US
dc.subjectGroundwateren_US
dc.subjectElectrical Resistivityen_US
dc.subjectGaratuen_US
dc.subjectAquiferen_US
dc.titleINVESTIGATION OF GROUNDWATER POTENTIAL USING ELECTRICAL RESISTIVITY METHOD AT GARATU SECONDARY SCHOOL, NIGER STATE, NIGERIAen_US