dc.description.abstractBuildings of al types are basically enclosures which house human activities and interests. Buildings ought to be designed, operated and be fit for people that use it, fit for its purpose, and fit for its planet. Post -Occupancy evaluation(POE) is the logical last step in a cylindrical design process, whereby lessons learned from he performance of building can be used to improve the performance of future designs. Post-occupancy evaluation (POE) of School of Environmental Technology building complex, Federal University of Technology,Minna,Niger State Nigeria was carried out. In order to achieve the aim of this paper, investigative POE methodology approach was adopted to collect data. one hundred and twenty questionnaires were distributed to staff and students who are the actual users of the building complex. A total of ninety -five completely filled questionnaires were retrieved and used for the analysis to ascertain the level of satisfaction of the occupants. The questionnaires were validated for reliability through pilot survey. of those respondents surveyed, 55% were students and 45% staff. 19% were women aged under 30, 24% over 30. 32% were men aged less than 30 and 25% over 30. The findings were compared with Building Use studies (BUS) database of educational buildings. user's perception is worst in the area of general cleanliness and maintenance of facility. The report generated from the user's perception of their working/learning environment could be used to aid building performance.en_US
dc.language.isoenen_US
dc.publisherConstruction Focus: Journal of Construction Management and engineering, Faculty of Environmental Design, Ahmadu Bello University, Zaria, Kaduna State, Nigeriaen_US
dc.subjectBuilding performance, design professionals, occupant's satisfaction, post-occupancy evaluationen_US
dc.titlePost-Occupancy Evaluation of the School of Environmental Technology building complex, University of Technology, Minna, Niger State, Nigeriaen_US
dc.typeArticleen_US
Appears in Collections:Architecture