Split-phase motor running as capacitor starts motor and as capacitor run motor

No Thumbnail Available

Date

2016-06-28

Journal Title

Journal ISSN

Volume Title

Publisher

Leonardo Electronic Journal of Practices and Technologies

Abstract

In this paper, the input parameters of a single phase split-phase induction motor is taken to investigate and to study the output performance characteristics of capacitor start and capacitor run induction motor. The value of these input parameters are used in the design characteristics of capacitor run and capacitor start motor with each motor connected to rated or standard capacitor in series with auxiliary winding or starting winding respectively for the normal operational condition. The magnitude of capacitor that will develop maximum torque in capacitor start motor and capacitor run motor are investigated and determined by simulation. Each of these capacitors is connected to the auxiliary winding of split-phase motor thereby transforming it into capacitor start or capacitor run motor. The starting current and starting torque of the split-phase motor (SPM), capacitor run motor (CRM) and capacitor star motor (CSM) are compared for their suitability in their operational performance and applications

Description

parameters of a single phase split-phase induction motor is taken to investigate and to study the output performance characteristics of capacitor start and capacitor run induction motor

Keywords

Auxiliary winding, Capacitor start motor, Capacitor run motor, Maximum torque, Split-phase motor, Standard capacitor, Starting current, Starting torque

Citation

ENESI, Y.A., TSADO, J., NWOHU, M., USMAN, A.U. and IMORU, O.A., 2016. Split-phase motor running as capacitor starts motor and as capacitor run motor.

Endorsement

Review

Supplemented By

Referenced By