Split-phase motor running as capacitor starts motor and as capacitor run motor
No Thumbnail Available
Date
2016-06-28
Journal Title
Journal ISSN
Volume Title
Publisher
Leonardo Electronic Journal of Practices and Technologies
Abstract
In this paper, the input parameters of a single phase split-phase induction
motor is taken to investigate and to study the output performance
characteristics of capacitor start and capacitor run induction motor. The value
of these input parameters are used in the design characteristics of capacitor
run and capacitor start motor with each motor connected to rated or standard
capacitor in series with auxiliary winding or starting winding respectively for
the normal operational condition. The magnitude of capacitor that will
develop maximum torque in capacitor start motor and capacitor run motor are
investigated and determined by simulation. Each of these capacitors is
connected to the auxiliary winding of split-phase motor thereby transforming
it into capacitor start or capacitor run motor. The starting current and starting
torque of the split-phase motor (SPM), capacitor run motor (CRM) and
capacitor star motor (CSM) are compared for their suitability in their
operational performance and applications
Description
parameters of a single phase split-phase induction
motor is taken to investigate and to study the output performance
characteristics of capacitor start and capacitor run induction motor
Keywords
Auxiliary winding, Capacitor start motor, Capacitor run motor, Maximum torque, Split-phase motor, Standard capacitor, Starting current, Starting torque
Citation