Pedestrian-level Air Flow and Ventilation around Adjacent Buildings in Step-up Configuration
No Thumbnail Available
Files
Date
2017-08-24
Authors
Journal Title
Journal ISSN
Volume Title
Publisher
Nigeria Journal of Engineering and Applied Sciences (NJEAS), FUT Minna
Abstract
The outdoor air ventilation impact of a taller building at a downwind location in a layout of two
adjacent buildings in different step-up configurations is presented in this paper. The criteria for
ventilation assessment adopted are dimensionless parameters called velocity ratio (VR) and air
ventilation rate (AER), and the parameters examined are the separation distance (WV) between the
buildings and the ratio of height of downwind building to that of upwind building, herein referred to
as building height ratio (HR). A three-dimensional (3-D) numerical simulation employing the
Computational Fluid Dynamics (CFD) technique based on Reynolds-Averaged Navier-Stokes (RANS)
equation and Realizable k-ε turbulence model was used to study the turbulent flow field around
various full-scale size configurations of the adjacent buildings. Results show that while VR generally
increases with height ratio, it increases with separation distance until a certain maximum distance
which depends on the height ratio. AER on the other hand generally increases with height ratio, but
decreases with separation distance. The results indicate that greater air motion is induced at the
pedestrian level as the height of the downwind building increases, and greater rate of air flow is
exchanged between the buildings cavity and the surroundings. Based on the VR results obtained for
the building configurations examined, a separation distance of between 18 m and 30 m is proposed for
configurations 2.0 ≤HR≤ 3.0, and between 18 m and 24 m for configurations HR = 1.0 and 1.5, to
maximally invigorate the pedestrian-level air flow.
Description
Keywords
Separation distance, Building height ratio, Adjacent buildings, Computational Fluid Dynamics, Outdoor air ventilation