Geoelectrical Investigation on Road Failure of part of London Road Minna, Nigeria
No Thumbnail Available
Files
Date
2020
Journal Title
Journal ISSN
Volume Title
Publisher
Dutse Journal of Pure and Applied Sciences (DUJOPAS)
Abstract
An electrical resistivity method involving Wenner technique was carried out at part of London Road
Minna, Niger State. The aim of the study was to investigate the causes of road failure. Two profiles
parallel to the road of the study area of 300 m in length were investigated using Wenner array electrical
configuration method. The electrode spacing was at equal interval of 7.5 m and current was sent into
the ground using both current electrodes while potential electrodes received the signal which is display
by the terrameters in resistivity. A total of 42 electrodes were probed. The calculated apparent resistivity
pseudo section of profile A shows low resistivity. At the distance between 205 - 250 m the
material is of low resistivity which can also lead to failure of the road. Profile B shows some
anomalies between the distances of 45-60 m which is likely to be clay.