Applied Geophysics
Permanent URI for this collectionhttp://197.211.34.35:4000/handle/123456789/190
Applied Geophysics
Browse
2 results
Search Results
Item Analysis of Electrical Resistivity Survey Data for Aquifer Potential and Protective Capacity at Mararaba Dan-Daudu Minna, North Central, Nigeria(Science Publishing Group, 2023-10-28) Alfa Idris Alhaji; Salako Kazeem Adeyinka; Rafiu Abdulwaheed Adewuyi; Udensi Emmanuel Emeka; Adetona Abbas Adebayo; Jamilu ShehuIt is a fact that basement complex regions lacks sufficient overburden that can host sustainable water table, water bearing fractured/weathered rocks referred to as aquifers are usually identified via suitable geophysical methods to proffer solution to water challenges within these regions. This current study targets the exploration of groundwater potential within the Mararaba Dan-daudu community, a suburb of Minna metropolis. Electrical resistivity method was employed to delineate aquifer prospects and their protective capacity within the area of study. The data from thirty-six Vertical Electrical Sounding (VES) survey points were acquired and analysed. Survey points were aligned along six profiles (A – F) with six VES points per profile. Interpretation of VES points along profiles was helpful in determining the number of layers and thickness. The analysis revealed mainly three layers comprising of sand and fresh laterite at the first layer, fractured/weathered basement at the second layer and fresh basement at the third layer. Iso-resistivity mapping was also done at various depths (surface, 5 m, 10 m, 15 m, 20 m, 30 m and 40 m) respectively to investigate the lateral variations of resistivity over a horizontal plane. These showcased the electrical conductance sliced at the depths of interest. Thirteen VES points (A1, A5, A6, B1, B3, B6, C6, D6, E6, F1, F2, F4 and F5) were mapped as having good prospective aquifer properties. Longitudinal conductance was computed for the outlined VES points to determine their Aquifer Protective Capacity (APC). The result of (APC) rating for the 13 VES revealed the frequency and percentage of APC ranged as: 2 VES locations (15.4%) have good APC, 8 VES locations (61.5%) have moderate APC and 3 VES location (23.1%) have weak APC. with only 3 VES locations out of 13 VES locations in the study area revealed weak APC, the results proved that the groundwater potential of the study area has moderately good APC.Item Geoelectrical Investigation of Groundwater Potential, at Bosso Campus, Minna, Niger State, Nigeria(Science Publoshing Group, 2019) ADETONA, Adebayo AbbassAbstract: Geoelectrical investigation of groundwater potential has been carried out at Bosso Staff Quarters Bosso campus, Federal university of Technology, Minna. The area is situated on latitude 90 38’55.8”N and 90 39’29.0”N and longitude 6031’19.7”E and 6031’46.7”E. the survey was carried out with the aim of delineating the potential area for groundwater development and depth to the groundwater within the study area. The Schlumbeger array was used to sound six profiles with a total of 36 Vertical Electrical Sounding (VES) points. The sounding interpretation results were used to generate geoelectric section. The orresponding geologic section were also generated which revealed the existence of three subsurface layers. These layers revealed the existence of three subsurface layers. These layers comprise the top soil, weathered/fractured basement and fresh basement. The results of this analysis are presented as curves of apparent resistivity versus depth, from the digitalized curves obtained from the IP2WIN software, sulfur 11 was used to generates iso-resistivity map at different depth. The analysis of results shows that the area is not appropriate for borehole drilling.