Repository logo
Communities & Collections
All of DSpace
  • English
  • العربية
  • বাংলা
  • Català
  • Čeština
  • Deutsch
  • Ελληνικά
  • Español
  • Suomi
  • Français
  • Gàidhlig
  • हिंदी
  • Magyar
  • Italiano
  • Қазақ
  • Latviešu
  • Nederlands
  • Polski
  • Português
  • Português do Brasil
  • Srpski (lat)
  • Српски
  • Svenska
  • Türkçe
  • Yкраї́нська
  • Tiếng Việt
Log In
New user? Click here to register.Have you forgotten your password?
  1. Home
  2. Browse by Author

Browsing by Author "Olorundare, .E. F."

Filter results by typing the first few letters
Now showing 1 - 1 of 1
  • Results Per Page
  • Sort Options
  • No Thumbnail Available
    Item
    PARAMETRIC STUDY ON NATURAL VENTILATION: A CASE STUDY OF ENGINEERING CENTRAL WORKSHOP, FEDERAL UNIVERSITY OF TECHNOLOGY MINNA
    (2nd Faculty of Engineering and Technology Conference (FETiCON 2024), 2024-06-02) Olorundare, .E. F.; Bori Ige
    This study provides a literature review on natural ventilation principles, factors affecting airflow, thermal comfort, and the use of Computational Fluid Dynamics (CFD) in building design. The researchers created a detailed 3D model of a workshop and conducted simulations using the DesignBuilder-EnergyPlus software suite. The simulations focused on thermal comfort and were performed on a baseline model with a window-to-wall ratio (WWR) of 30%. The results showed that occupants experienced thermal discomfort for 30.74% of the year, with the remaining 69.26% being comfortable, ranging from "hot" to "slightly warm" sensations. The study then explored the impact of different interventions. Implementing lighting control improved thermal comfort, resulting in a 1.37% increase in the number of hours occupants experienced comfort. The introduction of mechanical ventilation without cooling had a minimal impact on thermal comfort (1.17% improvement). However, when mechanical ventilation and scheduled cooling were combined, there was a significant improvement. The predicted thermal sensation ranged from "slightly warm" to "slightly cool," with most occupants experiencing "neutral" conditions. This strategy increased comfort hours by 14.62% compared to the baseline. While lighting control and mechanical ventilation with fans offered minimal benefits, the combination of mechanical ventilation and scheduled cooling significantly enhanced occupant comfort.

DSpace software copyright © 2002-2025 LYRASIS

  • Privacy policy
  • End User Agreement
  • Send Feedback
Repository logo COAR Notify